lab1
This is the result of the laboratory on a used oil run at 14449 KM. This result shows that expected metal wear particles registered zero reading. The silicon detected which is classified as dirt has a higher reading but classified later by the testing laboratory as inconsistent with historical data analysis reading. Meaning, what perceived to be dirt is not actually dirt but a friction modifier ingredient as mentioned by the Formulator himself.
lab2
This is the result of the laboratory on a used oil run at 19095 KM. This result shows that expected metal wears particles registered zero reading for Cr (Chromium) and Pb (Lead), while the other wear metals still passed the prescribed reading. The silicon detected which is classified as dirt has still higher reading but classified later by the testing laboratory as inconsistent with historical data analysis reading. Meaning, what perceived to be dirt is not actually dirt but a friction modifier ingredient as mentioned by the Formulator himself.
 